Richards Thermocouple and Temperature Sensor Catalog 16

Extension Wire - Multicable - Twisted Pairs and Overall Shielded -

Twisted Pairs, Individually & Overall Shielded (SD) - Stranded wire is standard.

Multicable extension wire is a cost effective and space saving method of running multiple sensor leads to the process instrumentation. Stranded wire is standard. Multicable extension wire is constructed to protect the thermocouple circuits from electrical interference. Overall shielded wire has an Aluminum Mylar Tape ( AMT ) covering the bundle of twisted wire pairs and a copper drain wire. This gives protection from external noise. Example: 20KX04-PP The individually and overall shielded wire ( SD ) has the Aluminum Mylar Tape ( AMT ) wrapped around each twisted pair and again over all of the pairs. A copper drain wire is included with each pair and a copper drain wire is included with the overall shielding. This gives excellent protec- tion against external and internal noise. Just add “ SD ” to the end of the part number . Example: 20KX04-PP-SD Numbers in the part numbers signify the number of pairs, i.e. 01 = 1 pair, 02 = 2 pairs, etc. Special limits can be specified by doubling the type letter in the part number. Example: 20KKX04-PP Stainless steel Over Braid is available for many wires. It is used to protect from abrasion and fraying of wires and is an electric shield- ing when grounded. Eight is the designation for 304 Stainless Steel - “ OB8 ”. Just added letters to the end of the part number. Example: 20JX02-PP-OB8 If a communications wire is required add “ CW ” to the end of the part number. Example: 20KX04-PP-CW

Type EX - For part numbers take KX numbers below and change them to EX

Color Code: Purple (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Purple .

Type JX - For part numbers take KX numbers below and change them to JX

Color Code: White (Positive, Magnetic, Iron) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Black .

Type TX - For part numbers take KX numbers below and change them to TX

Color Code: Blue (Positive, Non-magnetic, Copper) and RED (Negative, Magnetic, Constantan) Outer jacket - Blue.

Type KX - Multicable Extension Wire - Twisted Pairs, Overall Shielded

Part

Wire

No.

Wire

Jacket

Max.

Max.

Lbs./

Kgs,/

Nominal Size

Number

Gauge Pairs

Insulation

Insulation

°F

°C

1000 Ft. Kilometer

Inches

mm

16KX01-PP

16

1

Polyvinyl Plastic

Polyvinyl Plastic

30

49.7

.249

6.30

Single 221

Single 105

20KX01-PP 20KX02-PP 20KX04-PP 20KX08-PP 20KX12-PP 20KX24-PP

20 20 20 20 20 20

1 2 4 8

Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic

Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic

28 45 83

53.1 67.0

.205 .290 .350 .420 .495 .665

5.21 7.37 8.89

123.5 194.9 294.6 503.0

Overall 194

Overall 90

181 198 338

10.64 12.57 16.89

12 24

Color Code: Yellow (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Magnetic, Nickel, 5% Aluminum, Silicon) Outer jacket - Yellow .

Type KX - Multicable Extension Wire - Twisted Pairs, Individually & Overall Shielded (SD)

Part

Wire

No.

Wire

Jacket

Max.

Max.

Lbs./

Kgs,/

Nominal Size

Number

Gauge Pairs

Insulation

Insulation

°F

°C

1000 Ft. Kilometer

Inches

mm

16KX01-PP-SD

16

1

Polyvinyl Plastic

Polyvinyl Plastic

25

49.7

.252

6.30

Single 221

Single 105

20KX01-PP-SD 20KX02-PP-SD 20KX04-PP-SD 20KX08-PP-SD 20KX12-PP-SD 20KX24-PP-SD

20 20 20 20 20 20

1 2 4 8

Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic

Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic

28 51 94

53.1 75.9

.210 .295 .395 .455 .550 .842

5.33 7.49

139.8 211.3 327.4 636.9

10.03 11.56 13.97 21.39

Overall 194

Overall 90

142 220 428

12 24

Color Code: Yellow (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Magnetic, Nickel, 5% Aluminum, Silicon) Outer jacket - Yellow .

Page 122

Phone: 617.527.4385 Fax: 617.964.3746 Email: sales@asrichards.com