Richards Thermocouple Cat17 Brn
Extension Wire - Multicable - Twisted Pairs and Overall Shielded -
Twisted Pairs, Individually & Overall Shielded (SD) - Stranded wire is standard.
Multicable extension wire is a cost effective and space saving method of running multiple sensor leads to the process instrumentation. Stranded wire is standard. Multicable extension wire is constructed to protect the thermocouple circuits from electrical interference. Overall shielded wire has an Aluminum Mylar Tape ( AMT ) covering the bundle of twisted wire pairs and a copper drain wire. This gives protection from external noise. Example: 20KX04-PP The individually and overall shielded wire ( SD ) has the Aluminum Mylar Tape ( AMT ) wrapped around each twisted pair and again over all of the pairs. A copper drain wire is included with each pair and a copper drain wire is included with the overall shielding. This gives excellent protection against external and internal noise. Just add “ SD ” to the end of the part number . Example: 20KX04-PP-SD
Numbers in the part numbers signify the number of pairs, i.e. 01 = 1 pair, 02 = 2 pairs, etc.
Special limits can be specified by doubling the type letter in the part number.
Example: 20KKX04-PP
Stainless steel Over Braid is available for many wires. It is used to protect from abrasion and fraying of wires and is an electric shielding when grounded. Eight is the designation for 304 Stainless Steel - “ OB8 ”. Just added letters to the end of the part number.
Example: 20JX02-PP-OB8
If a communications wire is required add “ CW ” to the end of the part number.
Example: 20KX04-PP-CW
Type EX - For part numbers take KX numbers below and change them to EX
Color Code: Purple (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Purple .
Type JX - For part numbers take KX numbers below and change them to JX
Color Code: White (Positive, Magnetic, Iron) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Black .
Type TX - For part numbers take KX numbers below and change them to TX
Color Code: Blue (Positive, Non-magnetic, Copper) and RED (Negative, Magnetic, Constantan) Outer jacket - Blue.
Type KX - Multicable Extension Wire - Twisted Pairs, Overall Shielded
Part
Wire
No.
Wire
Jacket
Max.
Max.
Lbs./
Kgs,/
Nominal Size
Number
Gauge Pairs
Insulation
Insulation
°F
°C
1000 Ft. Kilometer
Inches
mm
16KX01-PP
16
1
Polyvinyl Plastic
Polyvinyl Plastic
30
49.7
.249
6.30
Single 221
Single 105
20KX01-PP 20KX02-PP 20KX04-PP 20KX08-PP 20KX12-PP
20 20 20 20 20
1 2 4 8 12
Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic
Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic
28 45 83
53.1 67.0
.205 .290 .350 .420 .495
5.21 7.37 8.89
123.5 194.9 294.6
Overall 194
Overall 90
181 198
10.64 12.57
Color Code: Yellow (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Magnetic, Nickel, 5% Aluminum, Silicon) Outer jacket - Yellow .
Type KX - Multicable Extension Wire - Twisted Pairs, Individually & Overall Shielded (SD)
Part
Wire
No.
Wire
Jacket
Max.
Max.
Lbs./
Kgs,/
Nominal Size
Number
Gauge Pairs
Insulation
Insulation
°F
°C
1000 Ft. Kilometer
Inches
mm
16KX01-PP-SD
16
1
Polyvinyl Plastic
Polyvinyl Plastic
25
49.7
.252
6.30
Single 221
Single 105
20KX01-PP-SD 20KX02-PP-SD 20KX04-PP-SD 20KX08-PP-SD 20KX12-PP-SD 20KX24-PP-SD
20 20 20 20 20 20
1 2 4 8
Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic
Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic Polyvinyl Plastic
28 51 94
53.1 75.9
.210 .295 .395 .455 .550 .842
5.33 7.49
139.8 211.3 327.4 636.9
10.03 11.56 13.97 21.39
Overall 194
Overall 90
142 220 428
12 24
Color Code: Yellow (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Magnetic, Nickel, 5% Aluminum, Silicon) Outer jacket - Yellow .
Page 124