Richards Thermocouple Cat17 Brn
Extension Wire - Insulated
Richards Extension wire is used to complete the circuit from the thermocouple element to the temperature instrument. The extension wire and the thermocouple wire must both be of the same calibration type to maintain the accuracy of the thermocouple. The polarity of each set of wires must also be maintained during the installation or errors will be introduced into the circuit. The RED wire is always the NEGATIVE leg of the extension wire. Extension wire is also color coded to help with identification and installation. See the extension wire color coding chart in this catalog and the coding under the tables. If the wire will be subject to repeated flexing, a stranded wire should be used to prevent conductor breakage. To specify stranded conductors, add a S to the end of the part number. For typical, non-flexing, ambient temperatures, indoor use, a 20 gauge (1.3 mm) solid conductor with PVC (Polyvinyl Plastic) insulation wire is an excellent choice. This wire is low cost and resistant to oils, chemicals, abrasion, moisture, and acids. Never install extension wire in the same conduit as power lines. This will cause interference and errors in the temperature readings. It is a good practice to keep the extension wire at least 1 foot away from power lines to maintain an accurate thermocouple circuit. Thermocouple extension wire can be supplied on spools or coils. Wire orders will be spooled plus or minus 10% of the quantity unless otherwise specified by the customer and indicated on the purchase order. If you require spooled wire just specify the part number and the footage. The extension wire part numbers below., specify the wire gauge, Type, and insulation material. Example: 50 Feet of 24JX-TT ( in the number 24JX-TT-ex the “ex” indicates “extruded” Teflon®) ! Notes: Special limits can be specified by doubling the type letter in the part number. Example: 20KKX-TT Stainless Steel Over Braid is available for many wires. It is used to protect from abrasion and fraying of wires and as an electric shielding when grounded. Eight is the designation for 304 Stainless Steel - “ OB8 ”; It is just added to the end of the part number. Example: 20JX-GG-OB8
Nickel vs. Nickel Moly thermocouples - can use Type KX extension wire at room temperature .
Type C thermocouples - can use Type RSX at room temperatures.
Type B thermocouples - can use ordinary copper wire for extension wire at room temperatures.
Type BX - Extension Wire
Part
Wire
Wire
Wire
Jacket
Max.
Max.
Lbs./
Kgs,/
Nominal Size
Number
Gauge Form
Insulation
Insulation
°F
°C
1000 Ft. Kilometer Inches
mm
20BX-TT
20
Solid Teflon TFE (Fused Tape) Teflon TFE (Fused Tape)
400
204
10.0
14.9
.12 x .06 3.1 x 1.5
Color Code: Gray (Positive, Non-magnetic, Copper Manganese and Red (Negative, Non-magnetic, Copper) Outer jacket - Gray .
Type EX - Extension Wire
Part
Wire
Wire
Wire
Jacket
Max.
Max.
Lbs./
Kgs,/
Nominal Size
Number
Gauge Form
Insulation
Insulation
°F
°C
1000 Ft. Kilometer Inches
mm
16EX-PP 16EX-TT
16 16
Solid Solid
Polyvinyl Plastic Teflon TFE (Fused Tape)
Polyvinyl Plastic Teflon TFE (Fused Tape)
220 400
104 204
25.0 25.0
37.2 37.2
.20 x .13 .16 x .10
5.1 x 3.3 4.1 x 2.5
20E-GG * 20EX-PP
20 20
Solid Solid
Fiberglass, Impregnated Polyvinyl Plastic
Fiberglass, Impregnated Polyvinyl Plastic
400 220
204 104
7.7 12.5
11.5 18.6
.09 x .06 .16 x .10
2.3 x 1.5 4.1 x 2.5
Color Code: Purple (Positive, Non-magnetic, Nickel, 10% Chromium) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Purple . * Thermocouple Grade quality - Overall Brown , if tracer - Purple .
Type JX - Extension Wire
Part
Wire
Wire
Wire
Jacket
Max. Max.
Lbs./
Kgs,/
Nominal Size
Number
Gauge
Form
Insulation
Insulation
°F
°C
1000 Ft. Kilometer Inches
mm
14JX-PP
14
Solid
Polyvinyl Plastic
Polyvinyl Plastic
220
104
34.5
51.3
.22 x .15 5.6 x 3.8
16JX-GG 16JX-GG-S
16 16 16 16 20 20 20 20 20
Solid Stranded
Fiberglass, Impregnated Fiberglass, Impregnated Polyvinyl Plastic Teflon TFE (Fused Tape) Fiberglass, Impregnated Polyvinyl Plastic Polyvinyl Plastic Teflon TFE (Fused Tape) Teflon FEP (Extruded)
Fiberglass, Impregnated Fiberglass, Impregnated Polyvinyl Plastic Teflon TFE (Fused Tape) Fiberglass, Impregnated Polyvinyl Plastic Polyvinyl Plastic Teflon TFE (Fused Tape) Teflon FEP (Extruded)
400 400 220 400 900 220 220 500 400
204 204 104 204 480 104 104 260 204
17.9 20.8 25.0 25.0 7.7 12.5 14.0 10.0 11.0
26.6 31.0 37.2 37.2 11.5 18.6 20.8 14.9 16.4
.15 x .09 .16 x .10 .20 X .13 .16 x .10 .09 x .06 .16 x .10 .19 x .11 .11 x .06 .12 x .07
3.8 x 2.2 4.1 x 2.5 5.1 X 3.3 4.1 x 2.5 2.3 x 1.5 4.1 x 2.5 4.7 x 2.7 2.7 x 1.6 3.1 x 1.8
16JX-PP 16JX-TT
Solid Solid
20J-GG * 20JX-PP 20JX-PP-S 20J-TT * 20JX-TT-ex
Solid Solid Stranded
Solid Solid
Color Code: White (Positive, Magnetic, Iron) and Red (Negative, Non-magnetic, Constantan) Outer jacket - Black . * Thermocouple Grade quality - Overall Brown , if tracer - Black or White.