Cat16 R2

Specialty Thermocouples & Attachments - Pipe & Washer Styles

The Richards pipe style are used to mount swaged (MgO) or miniature probe thermocouples to the outside surface of pipes. This will give a relative temperature of the pipe. The sensor is attached to the outside of the pipe by using a stainless steel band clamp. Richards RTDs can also be used with these types of attachments. Custom configurations of these items are available. Phone one of our sales engineers for details. Actual surface temperatures of pipes should be made by welding the positive and negative thermocouple wires on the pipe separate but close to each other.

Pipe Style Attachments - width of Stainless Steel band is 9/16”.

Range

Fits Pipe Size

Part Num- ber

Inches

mm

NPT

mm

Figure

PSCF10 PSCF16 PSCF20 PSCF28 PSCF40 PSBF10 PSBF16 PSBF20 PSBF28 PSBF40

7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3 7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3

22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2 22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2

3/4” 1”

26.7 33.5 42.2 48.3 60.5 to 73.0 26.7 33.5 42.2 48.3 60.5 to 73.0

1

For 1/8 NPT

1 1/4” 1 1/2” 2” to 1 1/2”

Compression Fitting (CF )

3/4” 1”

2

1 1/4” 1 1/2” 2” to 1 1/2”

Bayonet Fitting (BF)

Pipe Style Welded Bantam - Type K (for other types, change K to E , J , N , or T ) - width of Stainless Steel band is 9/16”. Range Fits Pipe Size

Part Number

Type

Inches

mm

NPT

mm

Figure

3

24K4BAM10-X-KM1 24K4BAM16-X-KM1 24K4BAM20-X-KM1 24K4BAM28-X-KM1 24K4BAM40-X-KM1

7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3

22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2

3/4” 1”

26.7 33.5 42.2 48.3 60.5 to 73.0

K

1 1/4” 1 1/2” 2” to 1 1/2”

1/8” OD Attached Miniature (AM)

4

24K4BDP10-X-Y 24K4BDP16-X-Y 24K4BDP20-X-Y 24K4BDP28-X-Y 24K4BDP40-X-Y

7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3

22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2

3/4” 1”

26.7 33.5 42.2 48.3 60.5 to 73.0

K

1 1/4” 1 1/2” 2” to 1 1/2”

1/8” O.D. Detachable Probe (DP)

X = Overall length Y = Probe length For other calibration types, change the “K” in the part number to “E”, “J”, “N”, or “T”. For detachable miniature thermocouple, change the BAM to BDM For attached probe, change BDP to BAP in the part number.

Washer Style Thermocouple -Type K From glass insulated wire (GG). Other insulations and overbraid (OB) also available.

Washer Outside Diameter

Washer Inside Diameter

Fits

Part Number

Inches

mm

Inch

mm Bolt / Screw

Construction

Washer Style (WS)

5

X

.260

20K4WSGG260 20K4WSGG210 20K4WSGG200

.575 .470 .610

14.61 11.94 15.49

.260 .210 .200

6.60 5.33 5.08

# 12 to 1/4” # 6 to # 8 # 6 to # 10

.210

X = Overall length For other calibration types, change the “K” in the part number to “E”, “J”, “N”, or “T”. 2” Leads Standard

Page 118

Phone: 617.527.4385 Fax: 617.964.3746 Email: sales@asrichards.com

Made with FlippingBook - Online Brochure Maker