Cat16 R2
Specialty Thermocouples & Attachments - Pipe & Washer Styles
The Richards pipe style are used to mount swaged (MgO) or miniature probe thermocouples to the outside surface of pipes. This will give a relative temperature of the pipe. The sensor is attached to the outside of the pipe by using a stainless steel band clamp. Richards RTDs can also be used with these types of attachments. Custom configurations of these items are available. Phone one of our sales engineers for details. Actual surface temperatures of pipes should be made by welding the positive and negative thermocouple wires on the pipe separate but close to each other.
Pipe Style Attachments - width of Stainless Steel band is 9/16”.
Range
Fits Pipe Size
Part Num- ber
Inches
mm
NPT
mm
Figure
PSCF10 PSCF16 PSCF20 PSCF28 PSCF40 PSBF10 PSBF16 PSBF20 PSBF28 PSBF40
7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3 7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3
22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2 22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2
3/4” 1”
26.7 33.5 42.2 48.3 60.5 to 73.0 26.7 33.5 42.2 48.3 60.5 to 73.0
1
For 1/8 NPT
1 1/4” 1 1/2” 2” to 1 1/2”
Compression Fitting (CF )
3/4” 1”
2
1 1/4” 1 1/2” 2” to 1 1/2”
Bayonet Fitting (BF)
Pipe Style Welded Bantam - Type K (for other types, change K to E , J , N , or T ) - width of Stainless Steel band is 9/16”. Range Fits Pipe Size
Part Number
Type
Inches
mm
NPT
mm
Figure
3
24K4BAM10-X-KM1 24K4BAM16-X-KM1 24K4BAM20-X-KM1 24K4BAM28-X-KM1 24K4BAM40-X-KM1
7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3
22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2
3/4” 1”
26.7 33.5 42.2 48.3 60.5 to 73.0
K
1 1/4” 1 1/2” 2” to 1 1/2”
1/8” OD Attached Miniature (AM)
4
24K4BDP10-X-Y 24K4BDP16-X-Y 24K4BDP20-X-Y 24K4BDP28-X-Y 24K4BDP40-X-Y
7/8 to 1 1 1/16 to 1 1/2 1 3/8 to 1 3/4 1 5/16 to 2 1/4 2 1/16 to 3
22.2 to 25.4 27.0 to 38.1 34.9 to 44.5 33.3 to 57.2 52.4 to 76.2
3/4” 1”
26.7 33.5 42.2 48.3 60.5 to 73.0
K
1 1/4” 1 1/2” 2” to 1 1/2”
1/8” O.D. Detachable Probe (DP)
X = Overall length Y = Probe length For other calibration types, change the “K” in the part number to “E”, “J”, “N”, or “T”. For detachable miniature thermocouple, change the BAM to BDM For attached probe, change BDP to BAP in the part number.
Washer Style Thermocouple -Type K From glass insulated wire (GG). Other insulations and overbraid (OB) also available.
Washer Outside Diameter
Washer Inside Diameter
Fits
Part Number
Inches
mm
Inch
mm Bolt / Screw
Construction
Washer Style (WS)
5
X
.260
20K4WSGG260 20K4WSGG210 20K4WSGG200
.575 .470 .610
14.61 11.94 15.49
.260 .210 .200
6.60 5.33 5.08
# 12 to 1/4” # 6 to # 8 # 6 to # 10
.210
X = Overall length For other calibration types, change the “K” in the part number to “E”, “J”, “N”, or “T”. 2” Leads Standard
Page 118
Phone: 617.527.4385 Fax: 617.964.3746 Email: sales@asrichards.com
Made with FlippingBook - Online Brochure Maker